Veridian Healthcare 08-352

Veridian Healthcare 08-352 manual

(1)
  • INSTRUCTIONS • ENGLISH
    Thank you for purchasing This 60-second digiTal ThermomeTer. read
    These insTrucTions carefully To ensure proper and safe operaTion of
    your ThermomeTer.
    60-SECOND DIGITAL THERMOMETER
    Model 08-352
    PROBE TIP
    D
    IGITAL DISPLAY
    POWER BUTTON
    B
    ATTERY CAP
    PLEASE READ AND SAVE THESE INSTRUCTIONS
    This product is not intended to diagnose or treat any health problem or disease and
    should not be used as a substitute for the consultation and advice of a physician or
    other medical professional.
    Thermometers should only be used under the supervision of an adult.
    This thermometer should be held during use; the patient should be seated or lying
    down during readings.
    Before use, it is recommended that the patient avoid eating, drinking, smoking or
    exercising for at least twenty minutes prior to taking a measurement. Never walk, run
    or talk during a measurement.
    NORMAL BODY TEMPERATURE AND FEVER
    Body temperature can vary from 97°F(36.1°C) and 99°F(37.2°C) and still be considered
    normal. The medically accepted ‘normal’ body temperature is 98.6°F. Body temperature is
    commonly lower in the morning than at any point during the rest of an individual’s waking
    hours. Temperature readings will vary based on the body location point of the reading. Oral
    temperature readings between 97°F(36.1°C) and 100°F(37.7°C) are considered normal. A
    rectal temperature reading is generally 1°F(0.5°C) higher; while an underarm, or axillary,
    temperature will be 1°F(0.5°C) lower.
    A fever is dened as a body temperature that is elevated above the normal for that
    person. It is important to determine what is normal for an individual before determining
    if a fever is present. Tracking an individual’s temperature on a consistent basis, at the
    same body site and at the same time everyday will help determine an individual’s normal
    temperature.
    FAHRENHEIT CELSIUS SWITCHABLE FEATURE
    This unit takes measurements in both Fahrenheit and Celsius. While the unit is OFF, press
    and hold the POWER button. After the brief self-test, the unit will show the last reading in
    either °F or °C. Continue to hold the POWER button, and display will change the mode and
    display the new temperature reading mode. Release the POWER button and begin your
    reading.
    MEMORY RECALL
    This unit includes a recall of the last measurement taken. When the unit is
    OFF, press the POWER button to turn the unit on, and release. After the self-
    test, the unit will briey show the last reading with an ‘M’ on the display.
    OPERATING INSTRUCTIONS
    Press and release the POWER button to activate the thermometer. The unit
    will beep and the display will show all of the digital display symbols as it
    performs a self-test before showing the last reading in memory.
    ‘Lo with a ashing °F will appear in the display, followed by a brief ash of
    98.6°F(37°C); the display will return to the ashing Lo, indicating that the
    thermometer is ready for measurement.
    ORAL USE
    1. Apply a probe cover if using.
    2. Place the probe under the tongue as near as possible to a
    heat pocket as noted in the diagram. Readings will be
    progressively lower the further the probe is from the
    indicated heat pockets.
    3. Hold the thermometer in place during the reading; do
    not bite down on the thermometer. The mouth must
    remain closed to ensure accurate results. The reading should take approximately thirty
    seconds.
    4. When the reading is complete and the peak temperature has been reached, the °F will
    cease ashing. If the reading is below 100°F(37.7°C), the unit will sound ten long beeps;
    if the reading is at or above 100°F(37.7°C), the unit will sound ten sets of three short
    beeps.
    5. To turn the unit o, simply press the POWER button. The unit will automatically shut-o
    after approximately ten minutes.
    UNDERARM (AXILLARY) USE
    1. Wipe the underarm with a dry towel before application.
    Apply a probe cover if using.
    2. Place the probe tip under the arm so that the tip is
    touching skin; hold the thermometer parallel, slightly
    angled upwards as indicated in the diagram. Position the
    arm across the chest to ensure the tip is completely
    covered.
    3. When the reading is complete and the peak temperature
    has been reached, the °F will cease ashing. If the reading
    is below 100°F(37.7°C), the unit will sound ten long beeps;
    if the reading is at or above 100°F(37.7°C), the unit will
    sound ten sets of three short beeps.
    4. To turn the unit o, simply press the POWER button. The
    unit will automatically shut-o after approximately ten minutes.
    Remember, axillary temperature readings are generally 1°F lower than oral readings.
    RECTAL USE
    1. Apply a probe cover if using. Apply a water-soluble lubricant for easier insertion.
    2. Lay the patient on their side or stomach with their legs hanging down.
    3. Gently insert the tip of the probe NO MORE THAN 1 INCH into the rectum. Stop
    immediately if you detect resistance. Always hold the thermometer in place during
    measurement.
    4. When the reading is complete and the peak temperature has been reached, the °F will
    cease ashing. If the reading is below 100°F(37.7°C), the unit will sound ten long beeps;
    if the reading is at or above 100°F(37.7°C), the unit will sound ten sets of three short
    beeps.
    5. To turn the unit o, simply press the POWER button. The unit will automatically shut-o
    after approximately ten minutes.
    Remember, rectal temperature readings are generally 1°F higher than oral readings.
    PROBE COVER USE
    Disposable, hygienic probe covers are recommended for use with stick thermometers to
    prevent contamination. Probe covers are intended for one-time use only; a new probe cover
    should be used with each application. Probe covers can commonly be found at your local
    retailer or can be ordered direct by using the attached order form.
    CARE AND CLEANING INSTRUCTIONS
    Store the unit in the provided protective case when not in use. Do not store the
    thermometer where it will be exposed to direct sunlight, dust or humidity. Avoid extreme
    temperatures. Do not attempt to disassemble the unit. If ERR displays and no measurement
    can be obtained, the unit must be replaced.
    Clean the thermometer by wiping with rubbing alcohol (70% isopropyl alcohol) or soap and
    water. Do not submerge in any liquid or autoclave. Wipe the thermometer with a dry cloth
    and allow to air dry.
    REPLACING THE BATTERY
    The low-battery indicator symbol will appear on the lower
    right of your display when the battery needs to be changed.
    1. Remove the battery cap by pulling gently.
    2. Looking at the unit from the back side (ratings label face
    up) carefully slide the battery tray out so the entire battery
    is exposed.
    3. Remove the battery with a non-metal tool. Do not attempt
    to remove the thin plastic battery cover bar.
    4. Replace the battery with a LR41 alkaline or SR41 silver
    oxide type battery with the positive (+) side facing up.
    5. Carefully replace the battery cap.
    6. Do not dispose of used batteries in the trash. Consult your
    local recycling center for the proper way to dispose of
    batteries in your area. Keep used batteries away from
    children, pets and excessive heat.
    HEAT
    POCKET
    HEAT
    POCKET
    ONE-YEAR LIMITED WARRANTY
    Congratulations on your purchase of a Digital Thermometer. Your Digital Thermometer is covered by the following
    limited warranty commencing upon the date of purchase, and subject to the following terms and conditions:
    The Warrantor warrants that its Digital Thermometer will be free from defects in materials and workmanship under
    normal consumer usage for a period of one year for the original purchaser of the Digital Thermometer.
    Periodic maintenance, repair and replacement of parts due to normal wear and tear are excluded from coverage.
    Defects or damage that result from: (a) improper operation, storage, misuse or abuse, accident or neglect, such as
    physical damage (cracks, scratches, etc.) to the surface of the product resulting from misuse; (b) contact with liquid,
    water, rain, extreme humidity or heavy perspiration, sand, dirt or the like, extreme heat, or food; (c) use of the
    Digital Thermometer for commercial purposes or subjecting the Digital Thermometer to abnormal usage or
    conditions; or (d) other acts which are not the fault of the Warrantor, are excluded from coverage. This warranty
    does not cover batteries or other power sources that may be provided with, or used with the Digital Thermometer.
    If the Digital Thermometer fails to conform to this limited warranty, return the Digital Thermometer postage
    prepaid along with $5.00 for return shipping, handling and insurance to: Attn: Repair Department, 1175
    Lakeside Drive, Gurnee, IL, 60031. When returning a product, please also include: (i) a copy of your receipt, bill
    of sale or other comparable proof of purchase; (ii) a written description of the problem; and (iii) your name, address
    and telephone number. Carefully package the product to avoid any damage that may occur while in transit;
    shipping insurance with returned receipt is recommended. At our option, Veridian Healthcare will repair or replace
    the unit found to be defective in materials or workmanship under normal consumer usage. The purchaser will be
    notied of any additional repairs required prior to completing the repair, and will be responsible for parts charges, if
    any, and repair charges not covered by this limited warranty.
    EXCEPT AS PROVIDED FOR IN THIS LIMITED WARRANTY, ALL EXPRESS AND IMPLIED WARRANTIES AND CONDITIONS
    ARE DISCLAIMED, INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS
    FOR A PARTICULAR PURPOSE. THE REPAIR OR REPLACEMENT AS PROVIDED UNDER THIS LIMITED WARRANTY IS THE
    EXCLUSIVE REMEDY OF THE CONSUMER, AND IS PROVIDED IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.
    IN NO EVENT SHALL VERIDIAN HEALTHCARE BE LIABLE, WHETHER IN CONTRACT OR TORT (INCLUDING NEGLIGENCE)
    FOR DAMAGES IN EXCESS OF THE PURCHASE PRICE OF THE PRODUCT, OR FOR ANY INDIRECT, INCIDENTAL, SPECIAL OR
    CONSEQUENTIAL DAMAGES OF ANY KIND, OR FOR DAMAGES TO, OR LOSS OF, OTHER PROPERTY OR EQUIPMENT OR
    PERSONAL INJURIES TO THE FULL EXTENT THESE DAMAGES MAY BE DISCLAIMED BY LAW.
    Some states and jurisdictions do not allow the limitation or exclusion of incidental or consequential
    damages, or limitation on the length of an implied warranty, so the above limitations or exclusions
    may not apply to you. This warranty gives you specic legal rights, and you may also have other rights
    that vary from state to state or from one jurisdiction to another.
    Disposable Probe Covers 100 Pack (Model 08-322) Qty. _____ @ $5.00 ea. $________
    SUBTOTAL $________
    Illinois shipments add 8% Sales Tax $________
    Shipping, handling and insurance $ 3.00
    ORDER TOTAL $________
    SHIP TO ADDRESS:
    Name _________________________________________________________________
    Address _______________________________________________________________
    City ______________________________ State _____ Zip ________________________
    Daytime Telephone No. (_______)____________________________________________
    BILLING ADDRESS: If dierent from “SHIP TO” Address
    Name _________________________________________________________________
    Address _______________________________________________________________
    City ______________________________ State _____ Zip ________________________
    Daytime Telephone No. (_______)____________________________________________
    PAYMENT METHOD
    :
    Do not send cash
    ¢
    ¢
    Check or Money Order
    ¢
    ¢
    VISA
    ¢
    ¢
    MasterCard
    ¢
    ¢
    ¢
    Discover
    ¢
    ¢
    ¢
    Diners Club
    ¢
    ¢
    ¢
    American Express
    Card No. _______________________________________________________________
    Expiration Date _________________ Security Code_____________________________
    Signature ______________________________________________________________
    Print Name _____________________________________________________________
    Please allow 2 weeks for delivery. This order form is for shipment within the Continental U.S. and Canada.
    Thank You For Your Order!
    Please send a copy of this form with your check, credit card information or money order payable to:
    Veridian Healthcare, LLC
    Attn: Customer Service
    1175 Lakeside Drive
    Gurnee, IL 60031
    FAX CREDIT CARD ORDERS TO: 8664801717 QUESTIONS? 8663261313
    #93-1033 06/12
    PROBE COVER ORDER FORM
    SPECIFICATIONS
    B
    ATTERY: One 1.5V button size battery LR41 or equivalent
    B
    ATTERY LIFE: Approximately 24 months
    AUTOMATIC SHUT-OFF: Approximately after 10 minutes of non-use
    ACCURACY: ±0.2°F, 98.0°F - 102.0°F (±0.1°C, 37.0°C - 39.0°C )
    ±
    0.3°F, 96.4°F - 98.0°F (±0.2°C, 35.8°C - 37.0°C )
    ±0.3°F, 102.0°F - 106.0°F (±0.2°C, 39.0°C - 41.0°C )
    MEASUREMENT RANGE: 90.0°F – 109.9°F (32° – 42.99°C)
    O
    PERATING TEMPERATURE: 50.0°F – 104.0°F (10°C – 40°C)
    S
    TORAGE TEMPERATURE: 14.0°F – 140.0°F (-10°C – 60°C)
    DISPLAY: Liquid crystal display
    DISPLAY RESOLUTION: 4 digits (1/10th of a degree increments)
    D
    IMENSIONS: 5-1/8” X 3/4” X 3/8”
    WEIGHT: 0.38 ounces
    Specications are subject to change without notice.
    +
    Toll-Free Customer Care Help Line: 1-866-326-1313 Monday – Friday 8:30 a.m. – 4:30 p.m. CST
Veridian Healthcare 08-352

¿Necesitas ayuda?

Número de preguntas: 0

¿Tienes alguna pregunta sobre Veridian Healthcare 08-352 o necesitas ayuda? Haz tu pregunta aquí. Proporciona una descripción clara y completa de tu consulta. Cuantos más detallada sea tu consulta, más fácil será para otros Veridian Healthcare 08-352 propietarios responder adecuadamente a tu pregunta.

Ver el manual de Veridian Healthcare 08-352 aquí, gratis. Este manual pertenece a la categoría Termómetros y ha sido calificado por 1 personas con un promedio de 8.1 . Este manual está disponible en los siguientes idiomas: Spaans, Engels . ¿Tienes alguna pregunta sobre Veridian Healthcare 08-352 o necesitas ayuda? Haz tu pregunta aquí

Veridian Healthcare 08-352 especificaciones

General
Marca Veridian Healthcare
Modelo 08-352
Producto Termómetro
Idioma Spaans, Engels
Tipo de archivo PDF
Características
A prueba de agua
Tipo De contacto
Función memoria
Ubicación del termómetro Oral,Rectal,Underarm
Tiempo de medición 60
Configuración de la alarma de temperatura elevada
Color del producto Green,White
Unidad de medida °C,°F
Potencia
Apagado automático
Indicador de nivel de batería
Contenido del embalaje
Pilas incluidas
Estuche

Manual.ar

¿Buscas un manual?Manual.ar asegura que encontrarás el manual que está buscando en poco tiempo. Nuestra base de datos contiene más de 1 millón de manuales en PDF, de más de 10,000 marcas. Cada día añadimos los manuales más recientes para que siempre encuentres el producto que buscas. Es muy fácil: simplemente escribe el nombre de la marca y el tipo de producto en la barra de búsqueda y podrás ver instantáneamente el manual de tu elección en línea de forma gratuita.

Manual.ar

© Copyright 2021 Manual.ar. Todos los derechos reservados.

Usamos cookies con el objetivo de brindarte la mejor experiencia en nuestro sitio web. Si continúas utilizando este sitio, damos por sentado que estás satisfecho con él.